Digital Light Source Controller
The wavelength, size, radiation intensity, and other features of the product can be customized flexibly. You are welcome to consult!
CHARACTERISTICS
Shell material | Steel Plate |
Shell color | Black |
Dimensions | 120*350*180(H*L*W) |
Weight | 2.4kg |
Cooling method | Air cooling |
Number of channels | 6 |
Input voltage | AC100-240V (50/60Hz) |
The output voltage | 15V |
communication method | 100M network port |
Dimming | Level 256 ( adjust by buttons on the panel or host computer) |
Short circuit protection | Yes |
Overcurrent protection | Yes |
Drive mode | Constant current |
Trigger mode | edge triggering |
control precision | 10us |
internal trigger | Yes |
response delay | Less than 5us ( hardware inherent latency) |
Trigger frequency | Less than 30KHz |
Single channel output voltage | 15V |
Maximum total power of the controller | 180w |
Maximum total current of the controller | 8A (depending on load) |
Single channel maximum current | 2A |
Trigger frequency | Less than 3KHz |
Linkage mode | support (It can only follow the previous linkage, that is: CH2 can link with CH1, CCH3 cannot link with CH1 directly, CH3 can only link with CH2 in sequence, and CH2 can link with CH1.) |
PWM mode | Triggered multiple times during validity period (Work according to the timing sequence of lighting delay + lighting time) |
high level | Input pulse width controls lighting time (The lighting time is only controlled by the pulse width of the external signal) |
Operating temperature and humidity | Temperature: 0~30℃, Humidity: 20~85%RH (non-condensing) |
Storage temperature and humidity | Temperature: -20~60℃, Humidity: 20~85%RH (non-condensing) |
DESCRIPTION
- The digital power controller has 256 levels of adjustment, 100M Ethernet communication, trigger timing can be set to external trigger or internal trigger, the installation can be screw or DIN rail, minimum adjustment unit is 10us, and it has independent input and output for each channel.
- Connection steps:
Connect to power
Make sure the green light is flashing (program) is valid. If only the red light is always on (for digital controllers), the program is lost.
Open the host computer software, confirm the IP address of the controller, and make sure it is in the same local area network as the local host.
Refer to the user manual to set relevant channel parameters (correct parameters to prevent lamp burning)
Plug in the light source, external trigger input or software trigger (if supported) - Both constant voltage drive and constant current drive are available, and it depends on load automatically.
- It integrates constant light and stroboscopic light.